Installation instructionsAbsorption Refrigerator for Recreation Vehicles RM 8400 RM 8401 RM 8405 RM 8500 RM 8501 RM 8505 RM 8550 RM 8551
104.0 Installation instructionsThe unit and the exhaust duct system must bein principle installed so that it is accessible formaintenance work, can be
11Another unfavourable method of rear installa-tion is to install the air intake and exhaust gril-les (Fig. 10) at the side wall of the recreationvehi
12Fig. 12Fig. 11Fig. 131122installation recess above the refrigerator. Affixthe this plate to the caravan wall, do NOTattach to the refrigerator !Att
13In the event of high ambient temperatures,full performance of the cooling unit canonly be achieved by means of adequateventilation and extraction.Ve
14Correct mounting of the lower ventilation grillefacilitates access to the connections andfunctional parts during maintenance.Fig. 21Dometic recommen
15Fig. 23Seal the mounting framemaking it waterproof(does not apply formounting frames withintegral seal).1 Fig. 24Insert frame and screwinto position
16The exhaust gas duct system must be made insuch a manner as to achieve a completeextraction of combustion products to the out-side of living space.
17Model Height HSTDepth TSTRMS 8400 RMS 8401 RMS 8405 RMS 8460 RMS 8461 RMS 8465 RMS 8500 RMS 8501 RMS 8505RMS 8550RMS 8551 RMS 8555RMSL
18After the refrigerator is put in its final place,secure the screws into the wall of the recess.The screws must penetrate the casing of therefrigerat
19Fig. 40Model RML 8xxx12Fig. 43Fig. 45Fig. 46Fig. 44Model RML 8xxx, frameless decor panel12341.2.3.4.Decor panel dimensions :1169,5 +0/-1 mm 507,5 +
0.0 Unpacking and transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.0 General . . . . . . . . . . . . . . . . . . . . .
20Installation4.8 Gas installationThe refrigerator must be equipped with a gascock in the supply line to allow the supply tobe disconnected. Such a cu
21Fig. 48 The electrical installation must be in accordance with the national regulationsof the respective countries. The connection cables must be
22InstallationFig. 414.9.3 Cable connectionsPosition of the control electronics :The power supplies for electronics and hea-ting element are connecte
23InstallationFig. 43Contacts at the electronics:EarthMains connection (230 V AC)INput heating element(12 V DC)Electronics connection (12 V)D+ signal
24Installation4.9.4 D+ and solar connection (only for AES models)D+ signal connectionIn >Automatic Mode< the AES electronicsystem automatically
25InstallationFig. 44Circuit diagram RM(S) 8xx0 :4.9.5 Circuit diagramsABCD
26Circuit diagram RM(S) 8xx1, RM(S) 8xx5 :InstallationFig. 451CD BA
27Fan (optional) RM(S) 8xx1, RM(S) 8xx5 := 12V OUT / 12 V power supply for optional connections= Ground connection heating element 12VDC = Positive co
28www.dometic.com
3Lifting / carrying the refrigerator0.0 Unpacking and transportNOTOKOKOKDO NOT USE A FLAME TOCHECK FOR GASWARNING!Never use for lifting or carrying ot
41.0 GeneralGeneralOn installation of the appliance, the technicaland administrative regulations of the countryin which the vehicle will first be used
5GeneralAll information and guidance in these opera-ting instructions were prepared after takinginto consideration the applicable standardsand regulat
6Safety instructions2.0 Safety instructionsThis appliance is designed for storage of foodand storage of frozen food and making ice.The refrigerators o
7Description of model3.0 Description of model3.1 Model identificationThe rating plate is to be found on the inside ofthe refrigerator. It contains all
8Description of modelFig. 3Fig. 2RMS 8xxxRM 8xxxHBTRML 8xxxFig. 43.3 Technical dataRMS= stepped cabinetModel Dimensions Gross capacity Rating detai
9Description of modelSubject to technical changes. *Average consumption measured at an average ambient temperature of 25°C in pursuance of ISO Standar