Seitenansicht 6
4. Only
the entire cooling unit must project into
the duct as shown
5. Air passing thr
ough the duct must not be
pr
eheated by any source of heat
6. Ventilation grills, if used, must have openings
of at leas
t 200cm
2
each
During installation, please ensure the mains plug
is accessible at all times.
5. Using the appliance
To start the refrigerator connect the plug to the socket
outlet and switch on the socket. The cooling fins should
show signs of cooling after about 1-2 hours depending
on ambiant temperature.
5.1. Initial operation
The device must be plugged into a properly earthed
socket.
The miniCool starts automatically with a self-test.
The LED illuminates after plugging-in several times
and after that continuous light can be seen if the
door is open.
The miniCool achieves its operating temperature
after several hours.
5.2. Temperature regulation
The usual setting required is in the region of the middle
of the thermostat knob (Fig. 6), but this can vary with
conditions of load and installation. If it is found
necessary to alter the setting,the knob can be turned
to a higher symbol to produce a colder temperature, or
a lower symbol to produce a warmer temperature. The
effect of any adjustment can be checked by means of
a thermometer after leaving the refrigerator operating
for a further period to settle down again.
Figure 6.
6. Useful suggestion
Do not overfill the appliance. It is advisable to leave
some space between the products in the cabinet to
ensure efficient and even cooling. If the shelves are
packed too tightly there may be unacceptable
temperature variations.
7. Defrosting, cleaning and
maintenance
Frost will gradually form on the cooling surfaces
and it must not be allowed to become too thick
since it acts as an insulator and interferes with the
cooling.
The miniCool is fitted with a fully automatic, electronic
temperature regulator.
The frost will melt and the defrost water will run
through the drain tube from the drip channel into an
evaporating vessel located at the bottom rear of the
refrigerator. (Fig 7) The defrost water will evaporate
automatically into the circulating air and the vessel
will not need emptying manually.
If we want to switch off the unit, disconnect the
refrigerator from the electricity supply and leave the
cabinet door open. After defrosting the cabinet
interior should be wiped out with a clean, damp
cloth.
7.1. Automatic defrost function
The first defrosting phase commences 39 hours
after the initial operation and lasts for two hours.
After this, the device operates for 22 hours at a
time, followed by a defrosting period of 2 hours.
8. Interior light
Two light-emitting diodes (A) on an electronic PCB
illuminate the cooling compartment when the door
is opened.
Two sensors (B) control whether the door is open
or not and the LEDs will work accordingly.
Figure 8.
Figure 7.
A
A
B
B