Dometic RA140 Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
This refrigerator is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
15. Putting into operation
Technical data:
15.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
16. Environmental
protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen compound)
is used as a refrigerating agent in the refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
17. Recycling
After unpacking the appliance, the packing materials
should be delivered to a local collection site. At the
end of its useful lifetime, the appliance should be
delivered to a specialized collection and reprocessing
firm, which reclaims the usable materials. The rest is
properly destroyed.
Model EA 3100, EA 0300, EA 3080 EA 3120 EA 3140
EA 0301, EA 0302 RA 80 RA 140
Type MF20-60 MF20-60 MF20-60 MF20-60
Gross volume 31 litre 23 litre 31 litre 41 litre
Mains operation 240V (AC) 240V (AC) 240V (AC) 240V (AC)
Input 90W 90W 90W 90W
Energy consumption 0.97 kWh/24h 0,92 kWh/24h 0.99 kWh/24h 1.07 kWh/24h
Climate class N N N N
Refrigerant 159g H
2
O+86g NH
3
159g H
2
O+86g NH
3
159g H
2
O+86g NH
3
159g H
2
O+86g NH
3
This appliance complies with the following EEC
directives:
LVD-Directive 73/23/EEC with amendment
90/683/EEC
EMC-Directive 89/336/EEC,
and the following standard:
AS/NZS 335.2.24-2001
Printed by Océ Hungária Kft.
Rev.: 2006. 03. 16.
Seitenansicht 7
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare