13. Customer service
Before you call a service engineer, carry out the
following simple tests:
Before you call a service engineer, carry out the
following simple tests:
Is there a power failure? Check the fuses.
Is the plug firmly connected to the socket and is the
socket switched on? Check the socket by plugging
in another appliance, e.g. a table lamp.
Is the thermostat at the correct setting? (normally 3
or 4).
Has the door not been closed properly causing the
inside temperature to rise too quickly?
Is the refrigerator level?
Has the ventilation become obstructed?
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
This refrigerator is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
14. Putting into operation
Technical data:
14.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter „E“
or by the earth symbol or coloured green and
yellow.
The wire coloured blue must be connected to the
terminal „N“ or coloured black.
The wire coloured brown must be connected to the
terminal marked „L“ or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
15. Environmental
protection
information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen
compound) is used as a refrigerating agent in the
refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
Model RH 131 RH 141
Type MF20-60 MF20-60
Gross volume 31 litre 41 litre
Mains operation 110V (AC) 110V (AC)
Input 90W 90W
Energy consumption 0.9 kWh/24h 0,98 kWh/24h
Climate class N N
Refrigerant 159g H
2
O+86g NH
3
159g H
2
O+86g NH
3