Dometic RH131D Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
8
GB
If after checking all the above points, the refrigerator
is still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
This refrigerator is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
Refrigerators until serial number 634xxxxx are
equipped with overheating protection on the cooling
unit. An authorised service technician can check
whether this has been triggered or not.
Refrigerators from serial number 634xxxxx, instead of
having overheating protection, are equipped with a
second (evaporator) sensor.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
14. Putting into operation
Technical data:
14.1 Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
Model RH 131 RH 141
Type MF20-60 MF20-60
Gross volume 31 litres 41 litres
Mains operation 120V (AC) 120V (AC)
Input 90W 90W
Energy consumption 0,9 kWh/24h 0,98 kWh/24h
Climate class N N
Refrigerant 159g H
2
O + 86g NH
3
159g H
2
O + 86g NH
3
15. Environmental
protection information
The appliance does not contain any CFCs/HCFCs.
Ammonia (natural hydrogen and nitrogen
compound) is used as a refrigerating agent in the
refrigeration unit.
The ozone-friendly cyclopentane is activated as a
motive agent for the PU foam insulation.
Sodium chromate is used for corrosion protection
(less than 2 weight % of the coolant).
16. Recycling
After unpacking the appliance, the packing
materials should be delivered to a local collection
site. At the end of its useful lifetime, the appliance
should be delivered to a specialized collection and
reprocessing firm, which reclaims the usable
materials. The rest is properly destroyed.
This appliance complies with the following
directives:
ANSI/UL STD: 250
CAN/CSA - C22.2 No. 63 - 93
13. Customer service
Before you call a service engineer, carry out the
following simple tests:
Problem
The appliance does not
cool sufficiently
The appliance does not
cool at all
Possible cause
Thermostat control is set too low
Too much food to be cooled was put in
Door is not shut properly.
Refrigerator not level
Internal air circulation is restricted.
External air circulation is restricted.
CUC system stopped the operation
Plug is not connected to the mains
socket properly.
There is no voltage in the mains socket
Solution
Set to a higher position
Put in less food to be be cooled
Check if the door is shut
Level refrigerator
Provide inside cool air circulation.
Provide outside air circulation.
See operating instruction 5. 2.
Check if the connection is proper.
Check if there is voltage.
(eg. Connect a lamp to the socket)
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare