Dometic RM 5310 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Kühlschränke Dometic RM 5310 herunter. Dometic RM 5310 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Installation instructions

Installation instructionsAbsorption Refrigerator for Recreation Vehicles RM 5310 RM 5330 RM 5380MBA 11/2011N 1Type C40 / 110821 2690 - 99AUS / NZ

Seite 2 - Table of Contents

10InstallationAnother unfavourable method of rear installa-tion is to install the air intake and exhaust gril-les (Fig. 10) at the side wall of the re

Seite 3 - 0.0 Unpacking and transport

11InstallationFig. 12Fig. 11Fig. 131122installation recess above the refrigerator. Affixthe this plate to the caravan wall, do NOTattach to the refri

Seite 4 - 1.0 General

12InstallationIn the event of high ambient temperatures,full performance of the cooling unit canonly be achieved by means of adequateventilation and e

Seite 5 - 1.7 Environmental notices

13InstallationFig. 19Dometic recommends the A 1625 ventilationand flue gas extraction system which hasbeen tested and approved for this purpose.These

Seite 6 - 2.0 Safety instructions

14Fig. 20Fig. 24Seal the mounting framemaking it waterproof(does not apply formounting frames withintegral seal).1 Fig. 21Insert frame and screwinto p

Seite 7 - 5 3 1 0

15Fig. 254.5.1 Installation in the recessPush the appliance far enough into the recessuntil the front edge of the refrigerator casing isaligned with t

Seite 8 - 3.3 Technical data

16InstallationAfter the refrigerator is put in its final place,secure the screws into the wall of the recess.The screws must penetrate the casing of t

Seite 9 - 4.0 Installation instructions

17InstallationFig. 33* Specialised personnel are accredited experts who areable, by virtue of their training and knowledge, to vouchfor the correct in

Seite 10 - 4.1.2 Rear installation

18InstallationFig. 34 The electrical installation must be in accordance with the national regulationsof the respective countries. The connection cab

Seite 11

19InstallationFig. 354.9.3 Terminal blockConnections :A = Ground heating element DCB = Positive connection, h.e. DCC = Ground interior lightingD = Pos

Seite 12

0.0 Unpacking and transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.0 General . . . . . . . . . . . . . . . . . . . . .

Seite 13

20InstallationFig. 38Wiring diagram RM 5xx0 without interior lighting4.9.4 Wiring diagramsA = ground heating element 12VDCB = plus heating element 12V

Seite 14

21InstallationFig. 39Wiring diagram RM 5xx0 with interior lightA = ground heating element 12VDCB = plus heating element 12VDCC = ground interior light

Seite 18 - 4.9 Electrical installation

3DO NOT USE A FLAME TO CHECKFOR GAS LEAKS WARNING!Most LP gas appliances used in recreationalvehicles are vented to the outside of the vehicle.When pa

Seite 19 - 4.9.3 Terminal block

4General1.0 GeneralOn installation of the appliance, the technicaland administrative regulations of the countryin which the vehicle will first be used

Seite 20 - 4.9.4 Wiring diagrams

5GeneralAll information and guidance in these opera-ting instructions were prepared after takinginto consideration the applicable standardsand regulat

Seite 21

6Safety instructions2.0 Safety instructionsThis refrigerator is designed for installation inrecreation vehicles such as caravans ormotorhomes. The app

Seite 22

7Description of model3.0 Description of model3.1 Model identificationThe rating plate is to be found on the inside ofthe refrigerator. It contains all

Seite 23

83.3 Technical dataDescription of modelFig. 3Fig. 2RM 5310RM 5330HBTRM 5380Fig. 4RM 5310 RM 5330 RM 5380 618x486x474821x486x474821x486x47460 lit.70 l

Seite 24

9Installation4.0 Installation instructionsThe unit and the exhaust duct system must bein principle installed so that it is accessible formaintenance w