INSTALLATION ANDOPERATING INSTRUCTIONSREFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATIONNDR 1292USA Corporate Office CANADAService Office 2320 Industrial
10DESCRIPTION OF OPERATINGMODESAES/AUTO MODEWhen operating in the AES/AUTO mode, the AES/AUTOmode indicator lamp (B) will illuminate. The control sys-
11HOW TO USE THE REFRIGERATORFOOD STORAGE COMPARTMENTThe food storage compartment is completely closed andunventilated, which is necessary to maintain
12LOW AMBIENT CONTROLAll RV absorption refrigerators, while similar, operate alittle differently than your home refrigerator. Dometic de-signers and e
13The correct operating pressure is 11 inches of watercolumn. The correct place to take the LP gas pres-sure is at the test port just ahead of the bur
14TROUBLESHOOTINGThe Refrigerator Does Not Cool ProperlyA. Burner jet clogged.Clean. (See section Maintenance & Service, Item2. Periodic Maintenan
15CERTIFIED VENT SYSTEM KITSREFRIGERATOR KITMODEL NO. COMPONENTS PART NO.NDR 1292 5A Roof Base 3103633.XXX*Roof Cover 3103634.XXX*Lower Side Vent 3109
16Put a screwdriver into the slot of the shelf lock.Turn the screwdriver counterclockwise.Remove the shelf locks from the wire shelf.Insert the ends o
20MO-FO 0324
3Refrigerator control panelFIG. 2AESAUTOGASACOFFCHECKONCOLD12345 COLDEST1E3DB2ACFGLEGEND 2-WAY AES Model1. Main Power Button ON/OFF2. AES/AUTO/GAS Mod
4INSTALLATIONGENERAL INSTRUCTIONThis appliance is designed for storage of foods andstorage of frozen foods and making ice.This appliance is certified
512 Volts DC ConnectionThis refrigerator model require a continuous 12 volt DCsupply to maintain the automatic energy system.The connection is made to
62. Secure the refrigerator and the lower front strip withtwo screws: One screw through each hinge. SeeFIG 6.Step 2: Two screws installed in the top f
7CERTIFIED INSTALLATIONCertified installations require one roof vent and one lowerside vent.For “Certified Vent System Kits” see page 15.For further i
8OPERATINGINSTRUCTIONSIMPORTANCE OF LEVELING AREFRIGERATORIn an absorption refrigerator system, ammonia is lique-fied in the finned condenser coil at
9THERMOSTATThe thermostat on the refrigerator controls both the gasand electric operation, thereby eliminating the neces-sity of resetting each time a