SERVICE TIPS
Dometic
AMES/AES/ROYALE/ELlTE
REFRIGERATORS
Models
SILHOUETTE
AMES/AES
S1521
S1531
S1621
S1631
S1821
S1831
DOMETIC
DOMETIC
AMES/AES
ROYALE
RM2607
RM3662
RM2611
RM3663
RM2807
RM3862
RM2811
RM3863
RM3607
RM3807
DOMETIC
ELITE
RM4872
RM4873
Refrigerator Start-Up Information
The new Dometic Refrigerator has been designed to
provide more cooling power than ever before
-
surpassing all agency requirements and customer
expectations. When starting this refrigerator for the
very first time, the cooling cycle may require up to
four hours of running time before the cooling unit is
fully operational.
OS1662 3/97
1997 The
Dometic
Corporation
Seitenansicht 0
1 2 3 4 5 6 ... 37 38

Inhaltsverzeichnis

Seite 1 - SERVICE TIPS

SERVICE TIPS DometicAMES/AES/ROYALE/ELlTEREFRIGERATORSModelsSILHOUETTEAMES/AESS1521S1531S1621S1631S1821S1831DOMETICDOMETICAMES/AES ROYALERM2607 RM3662

Seite 2 - SYMPTOM

GAS MODEMove the mode selector button (2) to the UP position. The GAS mode indicator lamp (C) will illuminate.After 45 seconds the burner should be ig

Seite 3

The second standby mode of operation will execute when a failure of the temperature sensing device orassociated electronic circuitry occurs. If this s

Seite 4 - ICE MAKER SECTION

GAS MODEWhen operating in the GAS mode, the AES/AUTO (2) and AC/GAS (3) mode selector buttons must be inthe UP (OFF) position.The GAS mode provides LP

Seite 5 - AMES REFRIGERATOR OPERATION

GAS MODEWhen operating in the GAS mode, the GAS mode indicator lamp (C) will illuminate.The GAS mode provides LP gas operation only. The control syste

Seite 6 - AES REFRIGERATOR OPERATION

AC COMPONENTSHEATING ELEMENTRemove the heater leads from the lower circuit board and measure for proper resistance .You should obtain the following re

Seite 7 - SPECIAL FEATURES OF OPERATION

DC COMPONENTS -HEATING ELEMENTCheck the heating element with ohms resistance.You should obtain the following readings 10%:MODEL WATTSS1531 215S162121

Seite 8 - REFRIGERATOR OPERATION

THERMISTOR ADJUSTERDo an ohms resistance check across the terminals. Proper ohms reading is approximately 23,200 ohms 10%.THERMISTORADJUSTERTO THER-MI

Seite 9

IGNITERVerify proper voltage at the positive (+) and ground (-)terminals of the igniter. Remove high voltage cable froigniter. The igniter should prod

Seite 10 - The control

UPPER CIRCUIT BOARDNOTE: The PAL tester will allow for proper testing of the integrity of the upper and lower circuit boards.PAL is available from you

Seite 11 - ELITE REFRIGERATOR OPERATION

If you experience a problem on any of the above checks, verify the fuses on the lower circuit board aregood.If all checks prove to be good, and the re

Seite 12 - AC/GAS MODE

THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THES1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807,RM2811, RM3607, RM3807, RM3662, RM

Seite 13 - BATTERY PROTECTION SYSTEM

D. GAS MODE: Verify that the following components are good: upper circuit board, thermistor and 3-ampfuse.Check for voltage during trial-for-ianition

Seite 14 - DC VOLTAGE REQUIREMENTS

LP GAS REQUIREMENTSThe LP gas pressure to the refrigerator should be 11 inches water column with half of all BTU’s of theRV turned on. With all other

Seite 15 - THERMISTOR

ROYALE AND ELITEMODELSMANUAL SHUTOFF VALVEUse a quarter dollar or a slotted screwdriverto change positionSOLENOID VALVETHERMOCOUPLEPRESSURE TEST-PORT

Seite 16 - SOLENOID VALVE

FLUE CAP (AMES/AES MODELS ONLY)The flue cap is located at the top of the flue tube and is attached with a screw.FLUE TUBEFLUEThe flue tube must be cle

Seite 17 - OH 44026

INTERNAL WIRINGVerify the refrigerator is wired per the wiring diagram for the exact model you are working on. See thefollowing typical wiring diagram

Seite 18

ROYALE & ELITETYPICAL 2-WAYWIRING DIAGRAM293267500 @--BURNER BOARD DISPLAY BOARD POWER 3A 5A 120V AC CABLEJ EARTH I 0 VALVE LIGHT NAL BLOCK

Seite 19 - AES DISPLAY PANEL

ROYALE & ELITETYPICAL 3-WAYWIRING DIAGRAM293267600 HOUSING@-CIRCUIT BOARD DISPLAY EAR TH@CIRCUIT BOARD POWER 3A 5A VALVE 35A LIGHT BLOCK 12v DC PO

Seite 20

VENTILATIONThe coach vent system must be able to provide a way to direct the hot air, produced by the action of thecooling unit, out away from the ins

Seite 21 - LP GAS COMPONENTS

ROYALE AND ELITE MODELS:CONDENSATE WATER DRAIN HOSE: A 3/4" hole must be drilled through the flooring in the openingof the base plate on the rear

Seite 22

D. Replace the top decoration panel.Third: Two screws installed as shown in rear base.DOOR POSITIONThe door position canbe checked by observing any mi

Seite 23

SYMPTOMCAUSE7. Insufficient cooling on AC - cools properly on other mode(s)8. Insufficient cooling on DC - cools properly on other mode(s)9. Insuffici

Seite 24 - INTERNAL WIRING

COOLING UNITThe chemicals involved in the cooling process include hydrogen, ammonia, water, and a rust inhibiting agent.There are no repairs recommend

Seite 25 - 293267500

ICE MAKER OPERATIONThe refrigerator must be allowed to precool properly before starting the ice maker. The refrigerator has tobe connected to 120 volt

Seite 26 - LEVELING

MOLD THERMOSTATThis is a single-pole, single-throw, bimetal switch. It starts an ejection cycle by closing at 18°F 5”. Thereset temperature is T

Seite 27 - AIR LEAKS

TIMING MOTORThis is a low-wattage, stall-type motor which is geared to the timing cam and ice ejector. It is a one RPMmotor.Disconnect power to the ap

Seite 28 - AND ELITE MODELS:

NOTE THE RELATIVE POSITIONOF THESE COMPONENTS IN THEFOLLOWING SCHEMATICSEJECTORNON ENERGIZED ENERGIZED THERMOSTAT HEATERThis is a freeze Cycle. The m

Seite 29 - AMBIENT TEMPERATURE

LSHUT-OFF SWITCHTHERMOSTATWATERSOLENOID SWITCHNear the completion of the firstrevolution, the timimg cam closes thewater valve switch. However, since

Seite 30

SHlJT-OFF SWITCHTHERMOSTATMOLD HEATERHOLDING SWITCHNear the completion of the secondrevolution the timing cam againcloses the water valve switch. Thi

Seite 31 - ICE MAKER COMPONENTS

WIRINGRefer to the wiring diagram supplied with the unit you are working on, and make sure all wiring connec-tions are correct and tight.THIS IS AN EN

Seite 32 - MOLD SWITCHES



Seite 33 - OPERATION

ICE MAKER SECTIONSYMPTOM16. Ice Maker fails to start.17. Ice Maker won’t make ice.18. Keeps making ice and won’t shut off.19. Not making enough ice.20

Seite 34

AMES REFRIGERATOR OPERATION2-WAY DISPLAY PANEL3-WAY DISPLAY PANELMODELS INCLUDE: S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807, RM2

Seite 35 - SHUT-OFF SWITCH

DC MODE (3-Way Models Only)When operating in the DC mode, the DC mode indicator lamp (A) will be illuminated. All other modelamps will be off. The DC

Seite 36 - ICE MAKER

GAS MODEWhen operating in the GAS mode, the mode indicator lamp (E) will illuminate.The GAS mode provides LP gas operation only. The control system wi

Seite 37 - WIRING DIAGRAM

2-WAY DISPLAY PANEL 3-WAY DISPLAY PANELDB CEB C E FROYALE REFRIGERATOR OPERATIONMODELS INCLUDE: RM3662, RM3663, RM3662 and RM3863AUTO MODE (P-WAY MODE

Seite 38 - 

NOTE: DO NOT continue to reset GAS operation if the CHECK indicator lamp continues to beilluminated after several tries.Press the TEMPERATURE SELECTOR