Dometic RM2410 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
- 6 -
INSTALLATION INSTRUCTIONS
INSTALLING REFRIGERATOR
Make sure the oor is solid and level.
The refrigerator must be installed in a substantial enclosure
and must be level.
Do not install the appliance directly on carpeting. Carpet-
ing must be removed or protected by a metal or wood panel
beneath the appliance, which extends at least full width and
depth of the appliance.
All areas within the recess in which the refrigerator is
installed must be sealed. Make sure that there is a complete
seal between the front frame of the refrigerator and the
top, sides and bottom of the enclosure. A length of sealing
strip is applied to the rear surface of the front frame for this
purpose. Also, apply a sealing strip to the foremost oor of
the enclosure. The sealing should provide a complete isola-
tion of the appliance’s combustion system from the vehicle
interior. Be careful not to damage the sealing strip when the
refrigerator is put in place!
SECURING THE REFRIGERATOR
It is important to follow the sequence in securing refrigerator in
enclosure since failure in doing that can cause leakage between
the frame and cabinet!
Any space between the counter, storage area or ceiling and top
of the refrigerator greater den 1½ inches should be blocked.
The heat produced at the rear of the refrigerator will become
trapped in this space, making the top of the refrigerator hot and
reduce the efciency of the refrigerator.
After the refrigerator has been installed (ensuring a combustion
seal at the front frame), the refrigerator is to be secured in the
enclosure with six screws (not included).
Install the six screws in the following order:
Two screws installed through the front base.
Two screws installed in the top frame.
Two screws installed in the rear base.
CONNECTIONS
GAS CONNECTION
Hook up to the gas supply line is accomplished at the manual
gas valve, which is furnished with a 3/8” SAE (UNF 5/8” -18)
male are connection. All completed connections should be
checked for leaks with a non-corrosive commercial bubble
solution
1.
2.
3.
3 rd.
2 nd.
1 st.
The gas supply system must incorporate a pressure regulator
to maintain a supply pressure of not more than 11 inches water
column. When testing the gas supply system at test pressures:
> 1/2 psi - the refrigerator and its individual shutoff valve
must be disconnected from the gas supply piping system.
≤ 1/2 psi - the appliance must be isolated from the gas sup-
ply piping system by closing its individual manual shutoff
valve.
If detailed instructions on the installation and connection to the
gas supply are required, contact your dealer or distributor.
EXPLOSION HAZARD. Never use an open
ame to check for gas leaks. Failure to heed this
warning could cause an explosion resulting in
death or severe personal injury.
WARNING
!
Seitenansicht 5